POLYDAN 180-40 P ELAST. + HM GARDEN   
Plastic asphaltic sheets

 
 
Data Sheet Certificates Safety Data Sheet
 
POLYDAN 180-40 P ELAST. + HM GARDEN is a waterproofing sheet made of SBS modified bitumen mastic. Composed of a non-woven polyester felt reinforcement and covered on both sides with a polypropylene film. Bitumen is treated with special additives in order to deter root damage.
Tested according to standard EN test methods.

 Technical Data

TECHNICAL DATAVALUEUNITSTANDARD
External fire performancePND-UNE-EN 1187; UNE-EN 13501-5
Reaction to fireE-UNE-EN 11925-2; UNE-EN 13501-1
WatertightnessPasa-UNE-EN 1928
Longitudinal tensile strength900 ± 250N/5cmUNE-EN 12311-1
Transversal tensile strength650 ± 250N/5cmUNE-EN 12311-1
Longitudinal elongation at break45 ±15%UNE-EN 12311-1
Transversal elongation at break45 ±15%UNE-EN 12311-1
Resistance to root penetrationPasa-UNE-EN 13948
Resistance to static loading>20kgUNE-EN 12730
Resistance to impact>1500mmUNE-EN 12691
Longitudinal resistance to tearing (nail shank)PNDNUNE-EN 12310-1
Transversal resistance to tearing (nail shank)PNDNUNE-EN 12310-1
Joint strength: peel resistance PND-UNE-EN 12316-1
Joint strength: shear resistance650 ± 250-UNE-EN 12317-1
Flexibility at low temperature< -15ºCUNE-EN 1109
Humidity resistance factor20.000-UNE-EN 1931
Dangerous substancesPND--
Flexibility at low temperature (pliability) after aging-5 ± 5ºCUNE-EN 1109
Flow resistance at elevated temperature after aging100 ±10ºCUN-EN 1110

Pasa = Positive or correct No pasa = Negative PND = No performance determined - = Not necessary

 Addtitional Technical Data

ADDITIONAL DATA VALUEUNITSTANDARD
Mass per unit area (nominal)4.0kg/m²-
Nominal thickness3.5mm-
Flow resistance at elevated temperature>100ºCUN-EN 1110
Dimensional stability at elevated temperature (longitudinal)< 0.5%UNE-EN 1107-1
Dimensional stability at elevated temperature (transversal)< 0.5%UNE-EN 1107-1
Adhesion of granulesPND%UNE-EN 12039

Membranes thickness tolerance: = -0,3 mm, apart from membranes with thickness 2 and 2,4 mm whose tolerance is =-0,2 mm.
Membranes mass per unit area tolerance: -5% (mini) and +10% (maxi) from nominal value.

 Environmental Information

Environmental InformationDeclared ValueUnitsNorm
Pre-consumer Recycled Content0%-
Post-consumer Recycled Content35%-
Manufacturing LocationFontanar, Guadalajara (España)--
Volatile organic compounds (VOCs)50 (A+)*µg/m3ISO 16000-6:2006

* A+ classification according to Decree No. 2011-321 of 23 March 2011 the Ministry French Ecology, Sustainable Development, Transportation and Housing

 Standards and Certification

UNE-EN 13707 standard.
.UNE-EN 13969 standard
CE marking.

 Presentation

PRESENTATIONVALUEUNIT
Length10m
Width1m
Roll surface10m2
Rolls per pallet25rolls
Product Code141112-
  1. polypropylene film
  2. SBS modified bitumen
  3. non-woven polyester felt

 Indications and Important Recommendations

- The design of the roof should be considered in relation to its compatibility with the building as a whole, and account taken of the significance of materials which may be included for other reasons.
- The roof covering, including joints, parapets, abutments, gutters and outlets, should remain weathertight under the external action of rain, snow, ice, dead and imposed loads, wind loads, solar and night radiation, and the internal environment of the building.
- Falls should be provided to enable the roof to drain towards outlets, gulleys or gutters of sufficient capacity. Gutters and roof drainage should be designed appropriately.
- As failures in flat roofs are often caused by the harmful effects of moisture which is trapped during construction, it is essential that great care be taken to minimize such risks. Trapped water may be the result of the use of wet materials, water from in-situ concrete and wet screeds, or rain on unprotected construction.
- Be careful about damage from the limited foot traffic associated with installation and maintenance operations. Reasonable care should be taken to avoid sharp objects or concentrated loads. Where regular traffic is envisaged, ie maintenance of lift equipment, a walkway should be provided.
- On completion of the roof, the non-mineral finished membranes should have a surface finish applied.
- In the event of damage the membrane must be repaired as soon as possible with a patch of the membrane torch-bonded over the damaged area.
- On cap sheets it is possible that some localized loss of the mineral surfacing may occur, after some years, in areas where complex detailing of the roof design is incorporated.
- The membranes should be subjected to regular annual inspections and roof drains kept clear as is good practice with all roofing membranes.
- Differential movement between the waterproofing membrane and the substrate, or any overlaid insulation in inverted roofs, or other material should be taken into account in design. If necessary, movement joints should be made in the waterproofing membrane.

 Maintenance recommendations

Maintenance requirements for Danosa Roofing Products

The following maintenance checks must be adhered to:
- A general examination on the condition of the waterproofing and surrounding roof components.
- An inspection of all functional roofing elements including skylights, outlets, upstands, penetrations and any other visible roofing components.
- Clean outlets, drains, gutters and remove any debris from the roof.
- Periodic removal of mildew, moss, herbs or any other kind of vegetation that has been accumulation on the waterproofing.
- Periodic removal of possible sediments accumulated on the deck (silt, sledges, slate granules, etc) by occasional water accumulation.
- Periodic removal of debris and small objects that may have accumulated on the roof.
- Ensure surrounding structural elements are sound such as eaves, flashings, slate tiles and brickwork.
- Ensure that the waterproofing is in good condition and there are no blisters, damage or separation.
- Review the condition of the waterproofing (adherence to upstands, condition of overlaps, visual appearance, etc) and repair the defects observed.

These operations must be carried out twice a year, preferably at the beginning of spring or autumn and must be increased in case of decks or valleys with zero falls. It is also necessary to perform additional maintenance depending on the type of roof, location and proximity of roofs to areas with trees or in areas with high levels of pollution.

More details on the document Maintenance and repair recommendations for flat roofs waterproofed with modified bitumen sheets

 Handling, Storage and Conservation

- This product is neither toxic nor inflammable.
- Membranes should be stored carefully on clean dry level surfaces, under cover, protected from rain, sun, heat and cold temperatures and clear of the ground. The same protection should be given to materials temporarily kept outdoors or on the roof during construction.
- Membranes must be stored upright.
- Membranes should be taken to the roof as required for use.
- Membranes will be used on a FIFO basis (First In First Out).
- Do not stack one pallet on another pallet.
- In all cases, it must be taken into account Health and Safety standards at work, and the rules of good construction practice.
- Danosa recommends consulting the Safety Data Sheet of this product that is available permanently in www.danosa.com.

- This product is not toxic or flammable.
- It must be stored dry and protected from rain, sun, heat and low temperatures.
- It must be stored upright.
- Don’t store two pallets high.
- You must use the oldest batch of products first.
- No waterproofing works should be performed when weather conditions may be unsuitable. These include snow or ice on the roof, heavy rain, moisture, when there are strong winds.
- In all cases, the rules of health and safety at work and the rules of good construction practice should be considered.
- To store in racking at height the shelves must have three stringers or beams under the wooden pallet.
- Before handling the pallet you must check the status of the pallet and reinforce if necessary.
- If you are using a crane for handling purposes, you must ensure protection for others as stated on our packaging.
- Danosa advise you to consult the MSDS for this product which is available at www.danosa.com or may be obtained by writing to our Technical Department.

 Warning

The information contained in this document and any other advice provided, are given in good faith, based on DANOSA's current knowledge and experience when products are properly stored, handled and applied, in normal situations and in accordance with the recommendations of DANOSA. The information applies only to the application (s) and the product (s) to which reference is expressly made. In case of changes in the parameters of the application, or in case of a different application, consult the DANOSA Technical Service before using the DANOSA products. The information contained herein does not exonerate the responsibility of the building agents to test the products for the application and intended use, as well as their correct application in accordance with current legal regulations.